Modules for you
AIRADAR 3D Anatomy · Labeling

Lymph node station atlas

Mediastinal lymph node stations from a real patient's CT, in three dimensions and layer by layer. Click a station, see the node on its CT slice, test yourself.

14Stations
6Expert-labelled nodes
11Lesson
0.83Two-model agreement (median Dice)
Loading the atlas…
Axial
Loading the CT slices…
Coronal
Sagittal

Click a slice: the point is marked in 3D as well. Wheel: change slice. · Drag: rotate · Wheel: zoom · Click: select

Why are lymph node stations hard to learn?

We designed the atlas around five known problems in medical education.

2D diagram, 3D anatomy

Stations are taught from flat diagrams but recognised on CT slices in the clinic. The atlas links the 3D model and three CT slices: the point you click on a slice appears in 3D, the zone you pick in 3D appears on the slices.

Fuzzy borders

Experts agree least between 4R and 10R; 10 is also confused with 4 and 5. The border tour shows each critical border on its own slice and in 3D.

The right-left trap

In stations 2 and 4 the border is not the midline but the left wall of the trachea. The second stop of the tour shows this trap on the slice.

N1 or N2?

Taking an N1 node for N2 misstages the patient. The N staging mode paints every station's category for the side of the tumour.

Which procedure reaches it?

In EBUS training, recognising stations is one of the skills trainees find hardest. The access mode shows the stations EBUS, EUS, mediastinoscopy and VATS reach.

Sources: Rusch VW et al., J Thorac Oncol 2009;4:568–77 · BMC Pulm Med 2016 · arXiv 2102.06515 · J Thorac Dis (EBUS) · Osmangazi J Med

Expert-labelled nodes

The nodes drawn by the dataset's expert were separated one by one, measured and placed in their stations.

A note on measuring. RECIST 1.1 measures a lymph node by its short axis: under 10 mm counts as normal, 10–15 mm as non-target, 15 mm or more as a measurable target lesion. This atlas is for teaching; it does not diagnose.

How it was made, and how far to trust it

Every step is measured and shown. A number without a source is not on the page.

Open CT

A contrast chest CT from NCI Imaging Data Commons in which an expert drew the mediastinal nodes (CC BY 4.0).

Two independent models

TotalSegmentator segmented the anatomy, MOOSE the ribs and the digestive canal; where both drew a structure their agreement was measured.

Station rules

The IASLC map's boundaries were computed from structures on the CT: trachea, carina, aortic arch, left brachiocephalic vein, oesophagus.

Expert nodes

The dataset's expert label was split node by node, measured and placed in its station.

Closed surfaces

Every structure was meshed with 3D Slicer's surface settings; every surface is closed, without holes.

0.83Two-model agreementDice on the 29 structures both TotalSegmentator and MOOSE drew (median; lowest 0.77)
73/73Closed surfaces73 of 73 structures are closed, without holes
6Expert nodesThe dataset's expert label; 5.3 mL in total
14Station mapAutomatic and approximate; awaiting expert review
Agreement per structure (Dice)
colon0.94
duodenum0.92
esophagus0.90
rib left 10.79
rib left 100.82
rib left 110.84
rib left 120.78
rib left 20.81
rib left 30.80
rib left 40.77
rib left 50.83
rib left 60.84
rib left 70.86
rib left 80.85
rib left 90.85
rib right 10.83
rib right 100.80
rib right 110.82
rib right 120.79
rib right 20.81
rib right 30.81
rib right 40.82
rib right 50.83
rib right 60.84
rib right 70.83
rib right 80.81
rib right 90.82
small bowel0.94
sternum0.92

Limitations

  • The stations were drawn automatically by rules; the azygos vein and the left pulmonary artery have no label of their own, so the lower border of 4R and 4L is taken at the carina. Stations 9 (pulmonary ligament) and 11–14 (intrapulmonary) are not in this version.
  • The nodes come from a single case; their distribution does not represent a population.
  • The atlas is for teaching and research; it is not for diagnosis or staging.

On your own cases: station map and expert review

In AIRADAR Labeling a model finds the nodes, places them in their stations and measures them; a radiologist approves or corrects. Corrections are recorded and quality is measured on every case. Teams can also work from 3D Slicer.

  • Two independent models. TotalSegmentator segmented the anatomy, MOOSE the ribs and the digestive canal; where both drew a structure their agreement was measured.
  • Station rules. The IASLC map's boundaries were computed from structures on the CT: trachea, carina, aortic arch, left brachiocephalic vein, oesophagus.
  • Expert nodes. The dataset's expert label was split node by node, measured and placed in its station.

Source and licence. CT and expert node label: Mediastinal-Lymph-Node-SEG, NCI Imaging Data Commons, case_0566 (CC BY 4.0). Anatomy: TotalSegmentator 2.18 (Wasserthal et al., Radiology: AI 2023); ribs and digestive canal: MOOSE 3.2.2 (Shiyam Sundar et al., J Nucl Med 2022). Station boundaries: IASLC lymph node map (Rusch et al., J Thorac Oncol 2009). Processing, station computation and 3D model: AIRADAR.